Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
Int J Artif Organs ; 46(5): 289-294, 2023 May.
Article in English | MEDLINE | ID: covidwho-2294616

ABSTRACT

OBJECTIVE: Extracorporeal membrane oxygenation (ECMO) is an intervention used for patients with acute respiratory distress syndrome (ARDS) from COVID-19 who have failed conventional ventilatory strategies. Very few studies have given insight into the outcomes of pregnant and postpartum patients requiring ECMO support. METHODS: Single center, retrospective, observational study of female pregnant and postpartum patients suffering COVID-19 ARDS and requiring ECMO. RESULTS: Eight SARS-CoV-2 positive patients were identified. The average age was 31 ± 4 years, with Body Mass Indices (BMI) and SOFA scores ranging between 32-49 and 8-11, respectively. Two patients were pregnant at the time of ECMO initiation, two were peripartum, and four were postpartum. Five patients (63%) had bleeding, and one patient had a hysterectomy. Seven patients (88%) were supported by V-V ECMO and one with V-A ECMO. Patients had between one and three circuit exchanges due to oxygenator failure or clots in the circuit. All patients were in ICU between 7 and 74 days, with hospital length of stay between 8 and 81 days. All patients were weaned off ECMO and were successfully discharged from the hospital. All newborns were born via cesarean section, and all survived to discharge. CONCLUSION: Our study shows a 100% neonatal and maternal survival rate demonstrating that ECMO in this patient population is safe. These patients should be transferred to experienced high-volume ECMO centers with the ability to perform emergent cesarean sections. ECMO should be considered a life-saving therapy for pregnant women with severe COVID-19 with an overall excellent maternal and neonatal survival rate.


Subject(s)
COVID-19 , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Infant, Newborn , Humans , Female , Pregnancy , Adult , Extracorporeal Membrane Oxygenation/adverse effects , Retrospective Studies , Cesarean Section , COVID-19/complications , COVID-19/therapy , SARS-CoV-2 , Postpartum Period , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/therapy
2.
Am Heart J Plus ; 24: 100223, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2094982

ABSTRACT

Background: Patients with heart failure face increased morbidity and mortality when infected with COVID-19. The objective of this study was to evaluate the outcomes of patients with Heart Failure (HF), Left Ventricular Assist Devices (LVADs), or Heart Transplants (HTx) diagnosed with COVID-19 within an advanced HF practice. Methods: Out of 2635 patients followed, 96 patients were diagnosed with COVID-19 between March 2020 and January 2021. Median hospital length of stay (LOS), requirement for mechanical ventilation (MV), and mortality rate were evaluated. Results: The distribution of COVID-19 among the 96 patients was: HF = 43 (45 %), LVAD = 16 (17 %) and HTx = 37 (38 %). Among 43 HF patients, 5 (12 %) died, 18 (42 %) required hospitalization with an LOS of 7 days, 5 (12 %) required ICU and 4 (9 %) required MV. Of the 16 LVAD patients, 2 (13 %) died, 8 (50 %) required hospitalization with an LOS of 11 days, 3 (19 %) required ICU and 3 (19 %) required MV. Among 37 HTx patients, 7 (19 %) died, 23 (62 %) required hospitalization with an LOS of 9 days, 6 (16 %) required ICU and 6 (16 %) required MV. Conclusion: This report is among the first to describe the impact of COVID-19 on a diverse advanced HF practice. It highlights the risks associated with COVID-19 faced by the HF, LVAD and HTx patients. A 90-day mortality rate of 19 % with HTx patients acquiring COVID-19 is ominous as is a mortality rate of 12 % each for HF and LVAD patients. This clinical impact should serve as a reminder of unique challenges with these populations.

3.
Int J Artif Organs ; 45(12): 1006-1012, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2020840

ABSTRACT

OBJECTIVE: The ProtekDuo with oxygenator mimics veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) in veno-pulmonary (V-P) configuration. We have recently developed a new configuration by utilizing a 25 Fr multistage femoral venous drainage cannula and by returning oxygenated blood through both lumina of the double lumen ProtekDuo cannula (V-VP configuration), thereby creating partial right ventricular bypass and oxygenated blood flow of up to seven LPM. We investigated our experience with V-P and V-VP ECMO in patients suffering from COVID-19 acute respiratory distress syndrome (ARDS). METHODS: Single center, retrospective observational study. RESULTS: Of nine patients, one was initiated on V-A, two on V-P, and six on V-V ECMO. All patients were reconfigured to V-P and five patients in addition had V-VP ECMO configuration. All patients had at least one and up to three circuit exchanges. Patients were on ECMO support between 20 and 122 (55 ± 29) days, were in ICU between 46 and 161 (78 ± 40) days with a total hospital length of stay between 35 and 171 (82 ± 42) days. Six of nine (67%) patients could successfully be weaned off ECMO, survived, and were discharged. CONCLUSION: The ProtekDuo cannula in V-P configuration provides ECMO blood flow while reducing RV flow, wall-stress and dilatation, as well as oxygen consumption. The V-VP configuration is useful to provide high blood flows of up to seven LPM of oxygenated blood, and partial RV support without over-circulating the pulmonary vascular bed. Our results show that V-P and V-VP ECMO configurations are feasible, have good outcome and are without complications.


Subject(s)
COVID-19 , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Humans , Extracorporeal Membrane Oxygenation/methods , COVID-19/therapy , Respiratory Distress Syndrome/therapy , Cannula , Catheterization
SELECTION OF CITATIONS
SEARCH DETAIL